Product Description
PPowerSA-SUNm24-L PV Array Monitor
PV Array Monitor
PV Array monitor is specialized in the PV Monitoring System, convergng at most 10 channels of measuing modules. It is amounted in the combiner box or DC electric cabinet, with fine Layout and simple wiring.
Features:
1. PV Array current measurement
2. PV Array fault alarm and location
3 Fuse break fault alarm and location
4. PV array voltage measurement (Selectable)
5. PV array temp. Measurement(Selectable)
6. Lighting protection state monitoring (Selectable)
7. Output breaker state monitoring (Selectable)
8. Modbus Protocl
9. Maintenance tools
--- Data monitoring
--- Stated measuing accuracy of current, voltage and PV array temp.
Function and advantages:
Maximum 24 strings data collection
Amounted in the combiner box
Digital display
Fine layout and simple wiring
PV array current measurement
Fault alarm and location of PV arrays and fuse break
PV array measurement of voltage and temp. (Selectable)
State monitoring of lighting protection and output breakers (Selectable)
Communicating through MODBUS protocol
PC tools:
Data monitoring
Current measurement accuracy adjusting
Voltage measurement accuracy adjusting
PV array temp. Accuracy adjusting
Communication address setting
Communication speed setting
Technical Data
PV array input ≤ 24 channels 0-20Adc, accuracy 0.5%
Analog input 1 channel, 4-20mA/0-5V, accuracy 0.5%
Digital input 2 channels, passive dry contract
Communication port 1*RS485, 2500V photoelectric isolation
Communication mode 4KV(10/700us) (GB9043-1999)
Digital display Accurate to 0.01, error≤ 5%
Power supply 85~264Vac or 120~370Vdc or 18~36Vdc (selectable)
Power consumption ≤ 10W
Working temperature -35 to +70 degree (-31° F to +158° F)
Storage temperature -40 degree o+85 degree(-40° F to +185° F)
RH 5~95% no condensation
Communication port 4kv(10/700us)(GB9043-1999)
Lightning protection
(selectable)
Electrostatic discharge GB/T 17626-4-2 class 3
Fast transient bust GB/T 17626-4-4 class 3
Surge immunity GB/T 17626-4-5 class 3
PFMF GB/T 17626-4-5 class 4
Width*height*depth 317mm*44mm*80mm
Installation backplane wall-mount
PV Array Monitor
PV Array monitor is specialized in the PV Monitoring System, convergng at most 10 channels of measuing modules. It is amounted in the combiner box or DC electric cabinet, with fine Layout and simple wiring.
Features:
1. PV Array current measurement
2. PV Array fault alarm and location
3 Fuse break fault alarm and location
4. PV array voltage measurement (Selectable)
5. PV array temp. Measurement(Selectable)
6. Lighting protection state monitoring (Selectable)
7. Output breaker state monitoring (Selectable)
8. Modbus Protocl
9. Maintenance tools
--- Data monitoring
--- Stated measuing accuracy of current, voltage and PV array temp.
Function and advantages:
Maximum 24 strings data collection
Amounted in the combiner box
Digital display
Fine layout and simple wiring
PV array current measurement
Fault alarm and location of PV arrays and fuse break
PV array measurement of voltage and temp. (Selectable)
State monitoring of lighting protection and output breakers (Selectable)
Communicating through MODBUS protocol
PC tools:
Data monitoring
Current measurement accuracy adjusting
Voltage measurement accuracy adjusting
PV array temp. Accuracy adjusting
Communication address setting
Communication speed setting
Technical Data
PV array input ≤ 24 channels 0-20Adc, accuracy 0.5%
Analog input 1 channel, 4-20mA/0-5V, accuracy 0.5%
Digital input 2 channels, passive dry contract
Communication port 1*RS485, 2500V photoelectric isolation
Communication mode 4KV(10/700us) (GB9043-1999)
Digital display Accurate to 0.01, error≤ 5%
Power supply 85~264Vac or 120~370Vdc or 18~36Vdc (selectable)
Power consumption ≤ 10W
Working temperature -35 to +70 degree (-31° F to +158° F)
Storage temperature -40 degree o+85 degree(-40° F to +185° F)
RH 5~95% no condensation
Communication port 4kv(10/700us)(GB9043-1999)
Lightning protection
(selectable)
Electrostatic discharge GB/T 17626-4-2 class 3
Fast transient bust GB/T 17626-4-4 class 3
Surge immunity GB/T 17626-4-5 class 3
PFMF GB/T 17626-4-5 class 4
Width*height*depth 317mm*44mm*80mm
Installation backplane wall-mount
Send your message to this supplier
People who liked this also liked